ANTERION for cataract surgery planning

Transform your cataract surgery routine with ANTERION

IOL lenses can be imported and used with a wide range of established formulas.
IOL lenses can be imported and used with a wide range of established formulas.

The ANTERION® combines biometry with corneal topography and tomography, anterior chamber metrics, and high-resolution OCT imaging in a single, small, workflow efficient device. The ANTERION is a true multi-modality platform, ideally suited to high-throughput cataract clinics and surgical hubs.

Capture all the biometric data you need

The ANTERION Cataract App uses high-resolution swept-source OCT to generate the most important biometry measurements for cataract surgery planning: corneal analysis, anterior chamber depth, lens thickness, and axial length. ANTERION offers both spheric and toric IOL calculation, a comprehensive range of established IOL formulas, and provides the data to calculate the most suitable IOL for your patient, without changing devices.


Maps, colour scale, and power increments can be adjusted as per clinicians’ preferences.
Maps, colour scale, and power increments can be adjusted as per clinicians’ preferences.

 

Cornea analysis customised to your preferences

Add the ANTERION Cornea App and receive a comprehensive set of measurements for evaluation of the corneal geometry of your patients. Detailed topographic and tomographic data, conveniently accessible on the same platform, reduces the risk of refractive surprises during your cataract surgery planning. Visualise all relevant information using customisable templates, presets, and reports.


Swept-source OCT images power the ANTERION and allow visual confirmation of measurements.
Swept-source OCT images power the ANTERION and allow visual confirmation of measurements.

 

Measurements you can trust

Viewing the OCT images that generate the data helps you to confirm your measurements. Detect hidden anomalies, monitor change, compare pre- and post-operative metrics, and visualise surgical results. Several clinical studies provide evidence that ANTERION measurements are very repeatable1 and have high agreement with other devices2, making it easy to integrate ANTERION data into your existing workflows and calculation methods.


ANTERION is small, fast, and intuitive to use

 

Optimise your clinical workflow

With the ANTERION Cataract and Cornea Apps, all this data is at your fingertips with as few as one quick click of the joystick button. Save time and space by examining the patient at one device and efficiently work through patient backlogs. 

 


For more valuable information about our products, educational offerings, learning materials and events 
Subscribe to our Newsletter orContact us


 

1. ANTERION Repeatability Studies:
Shetty N, Kaweri L, Koshy A, Shetty R, Nuijts R, Roy AS. Repeatability of biometry measured by IOLMaster 700, Lenstar LS 900 and Anterion, and its impact on predicted intraocular lens power. J Cataract Refract Surg. 2020 Nov 23. doi: 10.1097/j.jcrs.0000000000000494

Schiano-Lomoriello D, Hoffer KJ, Abicca I, Savini G. Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices. Sci Rep. 2021 Jan 13;11(1):983. https://doi.org/10.1038/s41598-020-79674-4

Tañá-Rivero P, Aguilar-Córcoles S, Ruiz-Mesa R, Montés-Micó R. Repeatability of whole-cornea measurements using a new swept-source optical coherence tomographer. Eur J Ophthalmol. 2021 Jul;31(4):1709-1719. doi: 10.1177/1120672120944022

2. ANTERION Device Comparison Studies:

Fişuş AD, Hirnschall ND, Findl O. Comparison of 2 swept-source optical coherence tomography-based biometry devices. J Cataract Refract Surg. 2021 Jan 1;47(1):87-92. doi: 10.1097/j.jcrs.0000000000000373

Shetty N, Kaweri L, Koshy A, Shetty R, Nuijts R, Roy AS. Repeatability of biometry measured by IOLMaster 700, Lenstar LS 900 and Anterion, and its impact on predicted intraocular lens power. J Cataract Refract Surg. 2020 Nov 23. doi: 10.1097/j.jcrs.0000000000000494

Herber R, Lenk J, Pillunat LE, Raiskup F. Agreement and repeatability of corneal tomography in healthy eyes using a novel Swept-Source optical coherence tomographer, a rotating Scheimpflug camera and a dual Scheimpflug-Placido system. J Cataract Refract Surg. 2021 Jun 28.doi: 10.1097/j.jcrs.0000000000000734Abstract


Back to the overview